Triangle Tube boiler repair is different now, because the company has stopped operating and the boiler on your wall no longer has a factory behind it. Assurance HVAC Heating & Cooling still services these boilers across Toronto and the GTA, with TSSA-certified gas technicians, and we will tell you plainly what is repairable. See our boiler repair in Toronto page for how a visit works.
Key takeaways
- Triangle Tube’s site says it ceased operations effective November 3, 2025.
- Spare parts remain available through stocking distributors while supplies last, per the maker’s site.
- We still diagnose and repair existing units, and tell you when parts are the problem.
- Replacement planning starts early, ideally before a failure in the middle of winter.
- Our line is answered 24/7, and you approve a flat-rate price before work.
Last updated . Written and reviewed by the Assurance HVAC Heating & Cooling service team.
On this page
- What happened to Triangle Tube
- What no factory support means for an installed boiler
- Triangle Tube boiler repair and parts: what is realistic
- What we can still diagnose and fix
- Triangle Tube error codes on Prestige boilers
- When the part is the problem
- Triangle Tube boiler repair or replacement: how to decide
- Planning a replacement without a breakdown deadline
- Keep the label, the paperwork and the install date
- Safety on an older, unsupported boiler
- Booking a visit for your Triangle Tube
- Triangle Tube boiler repair questions
What happened to Triangle Tube
Triangle Tube’s own site (opens in a new tab) says it “has ceased operations effective November 3, 2025.” A U.S. Consumer Product Safety Commission page dated March 3, 2026 says Triangle Tube is no longer in business.
The site lists the product categories it sold as gas condensing boilers, gas condensing combi boilers, volume and indirect water heaters, heat exchangers, Wi-Fi products and accessories. If one of those is installed in your home, this page is for you.
What no factory support means for an installed boiler
It means the maker is no longer there to answer technical questions, take claims or supply parts directly. Your boiler does not stop working because of that, and a unit in good condition can keep heating for years.
What changes is the safety net. Triangle Tube’s site states that purchases after the cessation date carry no warranty. We do not imply any current factory support or warranty on any Triangle Tube boiler, and we cannot confirm whether any coverage remains on a boiler bought before that date, so do not plan around a claim.
Triangle Tube boiler repair and parts: what is realistic
Triangle Tube’s site says spare parts remain available through stocking distributors while supplies last. That is the honest picture: parts exist today, but the supply is finite, and it can shrink without notice.
For common wear parts, a repair is often still possible. For a major component, availability decides whether repair makes sense. We tell you what we can source before you spend anything, and we do not promise parts we cannot confirm.
What we can still diagnose and fix
Much of what goes wrong with a boiler is not brand-specific: pumps, valves, the expansion tank, pressure, air, venting, ignition and sensors. A TSSA-certified technician can test and repair those on an orphaned unit like any other.
- Circulator pumps and zone valves
- Expansion tank and pressure problems
- Air in the system and radiators that will not heat
- Condensate drain blockages on condensing units
- Ignition and flame sensing faults
- Leaks at joints, valves and fittings
Triangle Tube’s Prestige manual does list its lockout codes, set out below. Beyond what its manuals say, we do not guess at service procedures for these boilers.
Triangle Tube error codes on Prestige boilers
Triangle Tube’s Prestige Solo and Excellence user’s information manual (opens in a new tab) lists the lockout codes for the Prestige Solo 80 to 399 and Excellence 110 with the CTRLMax control. The lockout screen shows a message such as Low Water, a possible cure and how to reset, with the code in the lower right corner.
Manual reset lockouts stay until the boiler is reset, and the control allows five resets every 15 minutes. Automatic reset lockouts clear once the condition does. With no factory left to call, the code is a useful pointer to which part to test and source.
| Code | What it means | What to do |
|---|---|---|
| E1 | Failed ignition: the burner did not light after 5 attempts | Call a technician |
| E2 | False flame: flame detected before ignition | Call a technician |
| E3 | High boiler temperature: the boiler water reached its high limit | Book a repair |
| E5 | Blower speed wrong, or its speed signal is not reaching the control | Book a repair |
| E7 | High flue temperature; resets itself | Book a repair |
| E13 | Reset limit reached: 5 resets every 15 minutes | Stop resetting and call a technician |
| E19 | Flame lost after startup | Book a repair |
| E31 | Supply sensor open circuit | Book a repair |
| E34 | Low line voltage | Call a technician |
| E37 | Low water: pressure has fallen below 7.2 psi; resets itself once it returns | Check the pressure gauge and call a technician |
| E47 | Water pressure sensor disconnected or broken | Book a repair |
| E84 | Flue temperature passed the high limit 5 times | Book a repair |
Write down the code and the message above it. Our TSSA-certified gas technicians read the lockout history, which keeps the last eight lockouts, and test the part a code points to before anyone hunts for a replacement.
When the part is the problem
Some failures turn on one expensive or scarce component, such as a heat exchanger, a control board or a gas valve. When that happens, repair cost is only half the question. The other half is whether the part exists at all.
We will check availability through the supply chain before quoting, and we put the answer in writing. If a part cannot be found, we say so promptly, so you can plan a replacement instead of waiting on a repair that cannot happen.
Triangle Tube boiler repair or replacement: how to decide
Without a maker, replacement is a more serious option than it is for a supported brand. Condensing boilers typically last 15 to 20 years, so age still matters, but so does the risk of an unfixable failure.
| Situation | Leaning | Why |
|---|---|---|
| Routine wear part, still obtainable | Repair | Cost is modest and the boiler is otherwise sound |
| Major component needed, supply uncertain | Check first, then decide | A repair is no use if the part cannot be found |
| Boiler near or past 15 years, repeat faults | Plan replacement | Costs and risks keep rising |
| Safety concern, such as a leak or venting fault | Fix now, then reassess | Safety comes before cost |
Planning a replacement without a breakdown deadline
A planned replacement beats an emergency one. It lets you compare quotes, choose between a heat-only boiler and a combi, and schedule the work for mild weather instead of a no-heat night.
A replacement is sized to your home’s heat loss and your radiators or in-floor loops, with the vent and condensate planned, and condensing boilers are 90% AFUE or better. Our heat pump installation service is an alternative worth a look.
Keep the label, the paperwork and the install date
Photograph the boiler’s rating label, note the install date and keep any manuals. These help a technician identify the model, and they help any replacement quote reuse piping, vent routes and controls where that makes sense.
The pages we reviewed do not give Canadian warranty rules or serial-number date reading for Triangle Tube, so we do not offer any. Our maintenance plan keeps an older boiler checked each year.
Safety on an older, unsupported boiler
If you smell gas, leave the house and call Enbridge Gas on 1-866-763-5427 from outside. If a carbon monoxide alarm sounds, get everyone out and call 911. Keep working CO alarms in the home, and call us the same day for a leaking relief valve or a pressure gauge in the red.
Booking a visit for your Triangle Tube
Send the request form with whatever the label says and what the boiler is doing. A text confirms a two-hour arrival window, and the technician diagnoses and explains the options. You approve a flat-rate price before work starts.
We take emergency calls 24/7 and go out day or night when the heat is off. We serve Toronto, North York, Vaughan, Markham, Richmond Hill, Mississauga and Oakville, including boiler repair in Vaughan.
Assurance HVAC Heating & Cooling is an independent HVAC contractor, not affiliated with or authorized by Triangle Tube. Brand names are trademarks of their owners.
Triangle Tube boiler repair questions
Is Triangle Tube still in business?
No. Triangle Tube’s own site says it has ceased operations effective November 3, 2025, and a U.S. Consumer Product Safety Commission page dated March 3, 2026 says it is no longer in business. Existing boilers still run, but there is no factory behind them.
Does my Triangle Tube boiler still have a warranty?
We cannot confirm any coverage, and we do not imply current factory support or warranty. Triangle Tube’s site says purchases after November 3, 2025 carry no warranty. For a boiler bought before then, we cannot confirm what, if anything, still applies, so do not plan around a claim.
Can you still get parts for a Triangle Tube?
Triangle Tube’s site says spare parts remain available through stocking distributors while supplies last. We check what is obtainable before quoting a repair. Common wear parts are often available, while a major component may not be, and we tell you which before you commit.
Is it safe to keep running a Triangle Tube boiler?
A boiler in good condition that is tested and serviced can keep running. Some Triangle Tube boilers were the subject of a U.S. Consumer Product Safety Commission recall, so give us the model name from the label and we check it before advising. Keep CO alarms working, have it checked yearly, and call us the same day for leaks, lockouts or venting concerns.
Should I replace my Triangle Tube boiler now?
Not necessarily. Age, condition and how readily parts can be found decide it. Routine repairs can make sense on a sound boiler. If it is near 15 years old or keeps failing, planning a replacement before winter beats an emergency one. We give you both options with prices.
Do you service Triangle Tube boilers in Markham and Oakville?
Yes. Our technicians work on Triangle Tube boilers across Toronto and the GTA, including Markham, Oakville, Mississauga, Vaughan, Richmond Hill and North York. Use the request form with the details on your boiler’s label, and we book the first available visit.
What does a Triangle Tube boiler error code mean?
On a Prestige with the CTRLMax control, the code sits in the corner of the lockout screen. Triangle Tube’s manual lists E1 as failed ignition after 5 attempts and E37 as low water, with pressure below 7.2 psi. The table above covers the common ones. The list is for Prestige models, so give us the model name from the label.
How much does Triangle Tube boiler repair cost?
It depends on the fault and whether the part can be found. We diagnose, check what is obtainable, and then give you a flat-rate repair price, approved before any work starts. If a replacement is wiser, we show that quote beside the repair.
Need Triangle Tube boiler repair? We’ll call you back to book.
Send the form or call. You’ll get a confirmed arrival window and a price before any work starts.
Open 24/7, with technicians out day or night for no-heat and no-cooling emergencies