Navien water heater repair in Toronto

(647) 692-0819Open 24/7, day or night

Navien water heater repair on this page means Navien’s condensing tankless units, so there is no tank to drain and the problems look different: scale in the heat exchanger, a restricted vent, a condensate drain, or poor flow. Our TSSA-certified gas technicians work across Toronto and the GTA and quote a flat-rate price you approve first. For the full picture, see our water heater page.

Request a technician

Tell us what’s going on. We’ll call to confirm a time.

What do you need?
How soon? Optional
Add email, details or text updatesOptional

Or call (647) 692-0819Used only to book your visit. Privacy

Key takeaways

  • Our technicians service Navien condensing tankless water heaters across Toronto and the GTA.
  • Navien says descaling is needed every few years, depending on water hardness.
  • TSSA-certified gas technicians, with a flat-rate price you approve before any work.
  • Open 24/7, with technicians out day or night when hot water stops.
  • Scale, a restricted vent or a blocked condensate drain can stop a tankless unit heating.

Last updated . Written and reviewed by the Assurance HVAC Heating & Cooling service team.

On this page
  1. Navien tankless in brief: the NPE-A2 and NPE-S2 families
  2. What is different about repairing a tankless unit
  3. Signs a Navien water heater repair is due
  4. Descaling and annual service: what Navien states
  5. Navien error codes: what E003 and the other codes mean
  6. Safe checks before booking a Navien visit
  7. Venting and condensate on a condensing tankless
  8. Navien water heater repair or replacement: which one fits
  9. Owning or renting a tankless unit
  10. Leaks, gas smell and alarms
  11. Booking Navien water heater repair across the GTA
  12. Navien water heater repair questions

What is different about repairing a tankless unit

A tankless unit heats water only as it flows, so the faults tend to be about flow, gas, venting and scale rather than a stored tank. There is no anode rod to check and no sediment bed to flush from a tank.

  • Dual stainless steel heat exchangers, per the maker’s brochure, which scale can restrict
  • A stainless steel burner, running on natural gas or LP depending on the model
  • Built-in ComfortFlow recirculation on the NPE-A2
  • A backlit EZNav control panel on the NPE-A2 that displays temperature and water flow rate
  • Self-diagnostics, listed by Navien as a feature

Descaling and annual service: what Navien states

Navien’s Canadian comparison table lists annual service as recommended for its condensing units, and its FAQ says descaling needs to be done every few years, depending on how hard your water is. We do not give a fixed interval beyond what Navien states.

Descaling circulates a cleaning solution through the heat exchanger. Isolation valves on the water lines make it much simpler, so ask whether yours has them fitted. A maintenance plan keeps the yearly visit on the calendar.

Navien error codes: what E003 and the other codes mean

These codes are from Navien’s user’s information manual for the NPE-A2 and NPE-S2 condensing tankless models (NPE-180A2, NPE-210A2, NPE-240A2, NPE-180S2, NPE-210S2 and NPE-240S2). When a code shows on the front panel, the manual says you can try resetting the unit by pressing the Back button. Try that once. If the code comes back, the table explains it.

The complete chart is on pages 17 and 18 of Navien’s NPE-2 user manual (opens in a new tab). Some of its remedies, such as cleaning the intake air filter or flushing the heat exchanger, need the front cover off or a pump and hoses, so we list those as a repair visit.

Common Navien NPE-A2 and NPE-S2 error codes, from Navien’s user manual
CodeWhat it meansWhat to do
E003Ignition failureCheck that the main gas supply valve is open, then reset once. If it returns, book a repair
E004False flame detectionCall a technician
E012Flame lossBook a repair. Navien points to the intake air filter and the power cord’s ground
E016Overheating of the heat exchangerBook a repair. Navien’s remedy is cleaning the cold water inlet filter and flushing the heat exchanger
E030Exhaust overheating: the unit shuts down when flue temperature exceeds 149 °F (65 °C)Book a repair for the same inlet filter and flushing work
E109Abnormal operation: fan motorBook a repair. Navien’s remedy is cleaning the intake air filter
E110Abnormal air pressureMake sure the exhaust pipe outside is free of obstructions, such as snow. If it returns, book a repair
E407Hot water outlet thermistor (temperature sensor) open or short circuitCall a technician
E439Abnormal operation: flow sensorCall a technician
E515Abnormal operation: PCB (circuit board)Call a technician
E760Flushing/service alarmBook routine service, as the manual advises
E773Using the wrong gasCall a technician

Write down the code and what the unit was doing when it appeared, such as running a shower or sitting idle. Our TSSA-certified gas technicians read the code on site and test the part it points to before replacing anything.

Safe checks before booking a Navien visit

A few checks need no tools and can save a visit. Keep away from anything that smells like gas, and stop if you are unsure what you are looking at.

  • Check that the gas supply valve and both water valves are open
  • Look at the display and note anything that is not the usual temperature
  • Confirm the unit has power
  • Check whether the problem is at one tap or every hot tap
  • Make sure nothing is blocking the vent outside, such as snow or a nest

Venting and condensate on a condensing tankless

A condensing unit pulls so much heat from exhaust gas that the exhaust turns to water, which drains away as condensate. If that drain freezes, clogs or sags, the unit can lock out.

We check slope, trap and discharge point, plus the intake and exhaust runs. In a Toronto winter, an outdoor vent termination also needs a look after heavy snow.

Navien water heater repair or replacement: which one fits

A tankless unit typically lasts about 20 years, so repair is usually worth it for a mid-life fault. Replacement comes up when the heat exchanger is failing, parts are hard to source, or the repair price nears a new unit.

Repair or replace: tankless water heater guide
SituationUsual answer
Scale, flow or vent fault, unit under 15 yearsRepair
Control or sensor failure on a unit under 20 yearsRepair
Heat exchanger leakingReplace
Unit near 20 years with repeated faultsCompare quotes

Owning or renting a tankless unit

Tankless units tend to be a longer-term decision because they last about 20 years. If you plan to stay, owning one avoids a monthly charge. If you may move soon, a rental may fit better. We say nothing about rental companies, so compare your written terms with a flat-rate quote from us.

Leaks, gas smell and alarms

With no tank, a leak comes from a pipe, valve or the heat exchanger. Close the cold water supply valve to the unit and call us. If you smell gas, leave the house and call Enbridge Gas at 1-866-763-5427 from outside. A CO alarm means everyone goes outside and you call 911.

Booking Navien water heater repair across the GTA

Booked visits get a two-hour arrival window and a text. You approve a flat-rate price before we start, and repairs carry our written workmanship warranty. We serve Toronto, North York, Richmond Hill, Vaughan, Markham, Mississauga and Oakville.

See Mississauga water heater installation for a local example. Navien’s own tankless page (opens in a new tab) lists the lines and service notes.

Assurance HVAC Heating & Cooling is an independent HVAC contractor, not affiliated with or authorized by Navien. Brand names are trademarks of their owners.

FAQ

Navien water heater repair questions

How often should a Navien tankless be descaled?

Navien’s FAQ says descaling needs to be done every few years, depending on the hardness of your water. Its comparison table also lists annual service as recommended for condensing units. Harder water means scale builds faster, so a technician can judge the interval from what the heat exchanger looks like.

What does a Navien error code mean?

Navien’s user manual for the NPE-A2 and NPE-S2 explains each code, and the common ones are in the table above. E003 is an ignition failure, and the first check is that the main gas supply valve is open. E110 is abnormal air pressure, so make sure the exhaust pipe is clear. If a code returns after one reset, book a repair and tell us the code.

Is a Navien NPE-A2 different from an NPE-S2?

Navien describes NPE-A2 as advanced condensing units featuring ComfortFlow and NPE-S2 as standard ultra high-efficiency condensing units. Both are tankless. For repair, we still start with gas, flow, vent, condensate and scale, then test the part the symptoms point to.

Why is my tankless water only lukewarm?

Scale on the heat exchanger, a partly closed gas valve or a restricted vent are common causes. A mixing issue elsewhere in the plumbing can do it too. We test gas pressure and flow, inspect the exchanger, then give you a flat-rate price for the fix.

Do Navien units run on natural gas or propane?

Navien’s brochure lists natural gas or LP models. Check the label on your unit to see which one you have, since the gas type affects parts and settings. If it was changed or converted, tell the technician, because that changes what we check first.

Is annual service really needed on a tankless?

Navien’s Canadian site lists annual service as recommended for condensing units. A yearly visit lets a technician check the vent, condensate drain, burner and heat exchanger, and plan descaling. It is also a good moment to confirm isolation valves are in place.

Can you repair a Navien at night?

Yes. We are open 24/7 and technicians go out day or night for no-hot-water calls. You still get a flat-rate price to approve before any repair work begins. If a part is needed, we explain the options and how to stay safe in the meantime.

Book a visit

Need Navien water heater repair? We’ll call you back to book.

Send the form or call. You’ll get a confirmed arrival window and a price before any work starts.

(647) 692-0819

Open 24/7, with technicians out day or night for no-heat and no-cooling emergencies