Amana furnace repair works well when the technician knows which kind of Amana you have: a single-stage, two-stage or modulating model, with a multi-speed or variable-speed blower. We cover furnace repair in Toronto and the GTA, and this page explains how the stage and blower type change what we check, and what to do first.
Key takeaways
- Amana furnaces are made under licence by Daikin, and Amana’s appliances belong to Whirlpool.
- Single-stage, two-stage and modulating Amana furnaces fail in different ways.
- Have the model number and any display code ready when you call.
- TSSA-certified gas technicians and a flat-rate price before any work.
- Open 24/7 for no-heat emergencies across the GTA.
Last updated . Written and reviewed by the Assurance HVAC Heating & Cooling service team.
On this page
- Amana furnace repair starts with the stage and blower
- The Amana name: two companies, one name
- How Amana’s 90%+ furnaces are grouped
- What changes when your Amana is two-stage or modulating
- Common Amana furnace repairs
- Checks you can do before you call about your Amana
- Amana furnace codes on the ARVT96 and ADVT96
- Amana warranty and paperwork
- Is it worth repairing an older Amana furnace?
- Safety first, then how a visit works
- Amana furnace repair questions
Amana furnace repair starts with the stage and blower
The first thing we want to know is whether the furnace is single-stage, two-stage or modulating, and whether it has a multi-speed or a variable-speed blower. That tells us how many heat levels the furnace uses, how its gas valve works and what the blower motor is meant to do.
Look at the rating plate or the paperwork from the install for the model number. Reading it out when you call saves time on the phone and at the door.
The Amana name: two companies, one name
The Amana on a furnace and the Amana on a fridge are different businesses today. Goodman bought Amana in 1997, sold the home appliance business to Maytag in 2002, and still owns Amana’s air conditioner and furnace division, with Goodman now part of Daikin North America. Whirlpool owns Amana’s home appliances.
Amana’s own furnace page carries the footer “Manufactured under license by Daikin”. That is the wording we rely on, and we leave it there instead of guessing about which factory or parts a given unit uses.
How Amana’s 90%+ furnaces are grouped
Amana lists its 90%+ furnaces by how they heat and move air. These are US-site listings, so they describe the range the maker shows, not what is sold in Canada. The same page names the model families below.
| Type | Models named | What to expect when it fails |
|---|---|---|
| Modulating, variable-speed | ARVM97, ADVM97 (97%) | More electronics to test, steadier airflow when working |
| Two-stage, variable-speed | ARVT96, ADVT96 | Stage faults show as heat that cycles between high and low |
| Two-stage, multi-speed | AR9T96, AD9T96 | Blower speed taps and two-stage valve checked in turn |
| Single-stage, multi-speed | AR9S96, AD9S96 | The simplest start-up chain, with an ECM blower |
Amana marks the ARVM97, ADVM97, ARVT96 and ADVT96 as ComfortBridge models with a stainless steel tubular primary heat exchanger. We don’t describe ComfortBridge further because our sources don’t, so don’t expect us to promise how a given feature behaves.
What changes when your Amana is two-stage or modulating
A two-stage or modulating furnace has more to go wrong than a single-stage one, but also more to tell us when it does. The symptom often points at the stage that failed.
- Heat that runs only on low or only on high: the valve, a pressure switch or a stage relay
- A blower that ramps up and down more than it should: the ECM motor, its module or a dirty filter
- Uneven heat from room to room: ductwork or a blower stuck at a low speed
- Starts, then quits partway through a cycle: flame sensor, limit switch or a restricted vent
Common Amana furnace repairs
Most calls come back to the same handful of parts, whatever the stage. We test the sequence from the thermostat call to the blower start, and replace only the part that fails.
- Igniter and flame sensor, the usual reasons burners won’t light or won’t stay lit
- Inducer motor and pressure switch, which prove the vent is drawing
- Blower and ECM motor replacement, and cleaning a clogged blower wheel
- Control board faults and blown low-voltage fuses
- Condensate trap and drain clogs on 90%+ units
- Limit and rollout switches that keep tripping, which means finding why before replacing
Checks you can do before you call about your Amana
Start at the thermostat and work toward the furnace, stopping the moment anything seems unsafe or you would have to open a panel. These checks take about five minutes and cost nothing, and they rule out the simple causes first.
- Set the thermostat to Heat and raise the setpoint a few degrees
- Make sure the furnace switch and the breaker are on
- Replace a dirty filter and close the blower door fully (see our guide to a furnace blowing cold air if the vents feel cold)
- Clear snow from the outside pipes on a high-efficiency model, by hand
- Note the status light before cutting power, then try one reset at the switch
Amana furnace codes on the ARVT96 and ADVT96
The ARVT96 and ADVT96 two-stage, variable-speed furnaces report faults as a letter and number code on a 7-segment display on the control board. The meanings below come from Amana’s ARVT96 installation manual (opens in a new tab), pages 24 and 43 to 51, and apply only to those two models.
After an EE0 lockout the control tries again on its own after one hour. Note the code, but don’t keep cycling the power: if the cause is still there, the furnace simply locks out again.
| Code | What it means | What to do |
|---|---|---|
| IdL | Standing by with no call for heat | No action needed |
| nonE | The board has no 115 or 24 volt supply, a fuse has blown or a breaker has tripped | Check the furnace switch and breaker; if still dark, book a repair |
| EE0 | Three ignition attempts failed, or the flame dropped out once lit | Book a repair |
| EE2 | Low stage pressure switch stayed open: a blocked flue, intake or drain, the hose or the inducer | Clear snow from the outside vent and intake by hand; book a repair if it comes back |
| EE3 | Primary limit tripped because too little air crossed the heat exchanger | Change a dirty filter, then call a technician |
| EE6 | Low flame signal, often a dirty or shifted flame sensor, while heat keeps running | Book a repair |
| EE7 | Fault in the igniter circuit or the unit ground | Book a repair |
| EE9 | High stage pressure switch did not close, so the furnace heats on low only | Look for snow at the outdoor pipes, then book a repair |
| EEF | Condensate switch open; the manual points to the air conditioning coil’s drain pan, trap and piping | Call a technician |
| E11 | Rollout switch open | Call a technician |
| Eb9 | The blower is moving less air than the control asked for | Replace a clogged filter and open every supply register |
| EA0 | The R-32 sensor found a refrigerant leak, so heat stops and only the fan runs | Call a technician |
| Green LED by the R-32 sensor plug, blinking | The control is talking to the refrigerant sensor | No action needed |
Keep a note of the code and when it appeared, for example at start-up or an hour into heating. Our TSSA-certified gas technicians confirm it at the board and test the switch, sensor or motor it names before a part is changed.
Amana warranty and paperwork
Amana’s furnace page says its limited warranty is provided by the manufacturer. We can’t give you a length or registration deadline, because none of the pages we reviewed gave one for Canada. Check Amana’s Canadian warranty page for your model and keep your install invoice.
An Amana furnace repair from us carries our own written workmanship warranty, separate from anything the maker offers. Two tune-ups a year under our HVAC maintenance plan also help catch worn parts early.
Is it worth repairing an older Amana furnace?
Amana furnace repair is often the sensible choice if the fault is a single part and the furnace is under 15 years old. Gas furnaces typically last 15 to 20 years, and a modulating or variable-speed Amana adds electronics that cost more to replace than a simple igniter.
| What failed | Typical call |
|---|---|
| Igniter, flame sensor, pressure switch | Repair |
| ECM blower motor on a furnace under 15 years | Usually repair |
| Control board on a furnace past 15 years | Compare repair and replacement |
| Heat exchanger crack | Replace |
Safety first, then how a visit works
If you smell gas, leave and call Enbridge Gas at 1-866-763-5427 from outside; if a CO alarm sounds, get everyone out and call 911. Otherwise call us any hour: we are open 24/7, and technicians go out day or night for no-heat calls.
The technician diagnoses, gives you a flat-rate price and waits for your yes. For a local look at the same service, see furnace repair in Markham, or read the maker’s Amana furnace listing (opens in a new tab).
Assurance HVAC Heating & Cooling is an independent HVAC contractor, not affiliated with or authorized by Amana. Brand names are trademarks of their owners.
Amana furnace repair questions
Is my Amana furnace a Goodman or a Daikin?
Amana’s furnace page says it is manufactured under licence by Daikin, and Goodman owns Amana’s furnace and air conditioner division, with Goodman now part of Daikin North America. The labels on your unit are what count. We can’t say whether any parts are shared across those brands.
Is the Amana on my furnace related to Amana appliances?
Only by name. Goodman kept Amana’s furnace and air conditioner division after the home appliances were sold, and Whirlpool now owns the appliances. For a furnace you deal with the HVAC side, and an appliance manual or warranty will not help with a furnace problem.
What does ComfortBridge mean on an Amana furnace?
Amana marks the ARVM97, ADVM97, ARVT96 and ADVT96 as ComfortBridge models. Our sources don’t describe what the feature does, so we won’t claim how it works. If your model carries the badge, tell the technician when you book so they arrive ready for the electronics.
My Amana is two-stage. Why does it only run on low?
A two-stage furnace uses a low stage for mild weather and a high stage for hard demand. If it never reaches high, a stage relay, a pressure switch, the gas valve or a restricted vent could be the cause. A technician tests each in sequence, since the symptom alone doesn’t pinpoint the part.
Can you repair an Amana furnace with a variable-speed blower?
Yes. Amana lists variable-speed models with ECM blowers, and we repair blower motors, controls and the rest of the furnace. A variable-speed motor depends on a clean filter and open ducts, so we check airflow first and replace the motor only if it has actually failed, then confirm the new one runs at the speeds the control calls for.
Where is the model number on my Amana furnace?
Look for the rating plate on the unit itself, often inside the cabinet or on a side panel, and check any paperwork from the installer. We haven’t verified a location specific to Amana, so don’t take off panels to search. If you can’t find it, the technician will read it on arrival.
What does an Amana furnace flashing light mean?
On the ARVT96 and ADVT96 the board shows codes such as EE0, a lockout after three failed tries to light, and EE3, an open limit that often traces to a clogged filter. A blinking green LED beside the refrigerant sensor plug only means the sensor is talking to the board. Other Amana models use their own lists.
Do you work on Amana furnaces in Oakville and Mississauga?
Yes. We repair Amana furnaces in Toronto, North York, Richmond Hill, Vaughan, Markham, Mississauga and Oakville. A TSSA-certified gas technician handles each call, and you approve a flat-rate price before any work starts. If your furnace needs parts, we explain the repair before we begin it.
Need Amana furnace repair? We’ll call you back to book.
Send the form or call. You’ll get a confirmed arrival window and a price before any work starts.
Open 24/7, with technicians out day or night for no-heat and no-cooling emergencies