Skip to content
Gas furnace and water heater in a home basement
Brands we repair

Tempstar furnace repair in Toronto

(647) 692-0819Open 24/7, day or night

Tempstar furnace repair usually starts with a symptom, not a model number: the furnace cycles on and off, heats some rooms badly, or makes a new noise. We repair Tempstar furnaces across Toronto and the GTA as an independent contractor. This page works through those symptoms and what is behind them. For our usual process, see furnace repair in Toronto.

Request a technician

Tell us what’s going on. We’ll call to confirm a time.

What do you need?
How soon? Optional
Add email, details or text updatesOptional

Or call (647) 692-0819Used only to book your visit. Privacy

Key takeaways

  • Tempstar is a Carrier Global brand and an International Comfort Products brand.
  • Short cycling, weak heat and new noises usually trace to airflow, a sensor or ignition.
  • Gas smell: leave and call Enbridge Gas. CO alarm: get out and call 911.
  • Open 24/7 with a flat-rate price you approve before work begins.

Last updated . Written and reviewed by the Assurance HVAC Heating & Cooling service team.

On this page
  1. Tempstar in brief: a Carrier brand with three furnace series
  2. Tempstar furnace short cycling: why it turns on and off
  3. Tempstar furnace not blowing hot air in some rooms
  4. Tempstar furnace repair for banging, squealing and rattling
  5. Wi-Fi controls and the Ion Black System Control
  6. Parts we replace most on a Tempstar furnace
  7. Finding your Tempstar model and fault information
  8. Tempstar furnace codes on the F96VTN
  9. Tempstar furnace repair or a new furnace?
  10. Safety: gas smell and carbon monoxide
  11. Booking Tempstar furnace repair in the GTA
  12. Tempstar furnace repair questions

Tempstar in brief: a Carrier brand with three furnace series

Tempstar is one of Carrier Global’s brands and an International Comfort Products brand, a Carrier subsidiary based in Lewisburg, Tennessee. That places it alongside Carrier, Bryant and KeepRite as a sister brand. We never assume the parts are interchangeable, so we match each part to your unit’s label.

Tempstar’s US site lists furnace series called Ion, QuietComfort and Performance. We can’t confirm which are sold in Canada, and we couldn’t verify any Canadian Tempstar page, so we work from the label on your furnace.

Tempstar furnace short cycling: why it turns on and off

A furnace that starts, runs a few minutes and shuts down again is short cycling, and the cause is usually airflow, a sensor or the thermostat location. It wastes gas and wears parts, so it deserves a proper diagnosis and not repeated resets.

  • Restricted airflow from a dirty filter or closed registers makes the limit switch trip.
  • A coated flame sensor loses the flame signal, so the gas shuts off.
  • A blocked condensate drain or vent pipe trips the pressure switch.
  • An oversized furnace can heat the house too fast and shut off early.

Our guide to furnace short cycling goes through each cause in more detail.

Tempstar furnace not blowing hot air in some rooms

If the furnace runs and the air is warm at the unit but weak at the registers, the problem is often airflow and not the burners. A failing blower motor, a dirty blower wheel, a collapsed duct or a closed damper can all cut heat to the far rooms.

In many GTA homes the longest duct runs serve the upstairs bedrooms and finished basements, which is where weak heat shows first. We measure temperature at the supply and return before suggesting any repair.

Tempstar furnace repair for banging, squealing and rattling

Noise is a useful clue. A bang at start-up can mean delayed ignition, a squeal often comes from a worn blower motor bearing, and a rattle often comes from a loose panel or ductwork. We find the source before touching any parts.

Don’t ignore a new noise. Delayed ignition left alone can strain the burners and the heat exchanger. If the bang is loud or happens more than once, turn the furnace off and call us. We also look at the exhaust and intake for blockages that cause rough lighting.

Wi-Fi controls and the Ion Black System Control

Tempstar’s US site says its Ion series is paired with the Ion Black System Control, which offers Wi-Fi. A system control talks to the furnace, so a wiring fault, a lost network connection or a failed control can look like a furnace problem.

Tell us whether your wall control is original, and bring up any recent thermostat swaps. If the screen is blank, check the batteries or the furnace switch first. If the screen works but the furnace doesn’t respond, we test the control wiring.

Parts we replace most on a Tempstar furnace

These repairs cover the large majority of heating calls on any gas furnace, and a Tempstar is no exception. We replace the failed part, not the whole assembly, whenever the test results support that, and we show you the failed part when we can.

  • Hot surface igniter and flame sensor
  • Inducer motor and pressure switch
  • Limit switch
  • Blower motor, ECM module and run capacitor
  • Control board
  • Condensate trap and drain line

Finding your Tempstar model and fault information

We have no maker source for where Tempstar places its rating plate. A label with the model and serial numbers is normally inside the furnace door, and the next section explains the fault codes on the F96VTN.

Our technician reads the status on site and explains it in plain terms. Photograph the label and keep it with your invoices, because the model and install date matter for warranty and parts.

Tempstar furnace codes on the F96VTN

Tempstar lists the F96VTN in its QuietComfort series, a two-stage furnace with a variable-speed blower. Its status LED flashes a two-digit major code through the sight glass on the door, short flashes first and long flashes second, and the board’s display adds a minor digit. The codes below are from Tempstar’s F96VTN installation instructions (opens in a new tab), pages 55 and 75.

This list applies to the F96VTN and G96VTN Series B. Other Tempstar furnaces may flash a different set, so match your model to its door label.

Tempstar F96VTN Series B codes, per the service label (Fig. 59)
CodeWhat it meansWhat to do
13 (13.1)Lockout: a switch in the limit circuit (limit, draft safeguard, rollout or blocked vent) stayed open past 3 minutes; it clears itself in 3 hoursCall a technician
14 (14.1)Gas failed to light and prove flame in 4 attempts; auto-reset after 3 hoursBook a repair
15 (15.1)No blower rpm detected, so the control locked outBook a repair
31 (31.6)The high-heat pressure switch or its relay did not close, or reopenedBook a repair
32 (32.2)The low-heat pressure switch did not close or reopened; checks include a restricted vent and excessive windClear snow or ice from the outdoor vent by hand; book a repair if it comes back
33 (33.1)One of the main limit circuit switches opened, such as the limit or the flame rollout switch; a dirty filter heads the checklistFit a clean filter, then call a technician
34 (34.1)Ignition fault during four consecutive trialsBook a repair
41 (41.2)The blower motor is running but the control reads no RPMBook a repair
43 (43.1)The high-heat pressure switch closed before the low-heat switchBook a repair
46 (46.1)Momentary loss of power; heating restarts when the supply settlesNo action needed unless it recurs
Rapid flash (10.1)Line voltage polarity is reversedBook a repair

Write the code down along with what the furnace was doing. Stored codes survive a power cut and stay in memory for 72 hours of powered operation, which lets the TSSA-certified gas technician we send read them on site and test the named switch or part before replacing it.

Tempstar furnace repair or a new furnace?

Age is the first question. Gas furnaces typically last 15 to 20 years, so a ten-year-old unit with a failed igniter is a clear repair, and an 18-year-old unit with a failed board is a closer call. We give you the repair price first.

Repair or replace, by symptom
SymptomOften a repairOften a replacement
Won’t igniteIgniter, sensor, pressure switchCracked heat exchanger
Short cyclingFilter, sensor, drainFurnace badly oversized for the home
Weak heatBlower motor, ductworkOld unit with several failing parts
Noisy start-upIgnition adjustment, loose partsHeat exchanger damage

Safety: gas smell and carbon monoxide

If you smell gas, leave the house and call Enbridge Gas at 1-866-763-5427 from outside. If a CO alarm sounds, get everyone out and call 911. Ontario’s gas safety regulator, TSSA (opens in a new tab), licenses the technicians who work on gas appliances, and ours are TSSA-certified.

Booking Tempstar furnace repair in the GTA

We serve Toronto, Mississauga, Oakville, Vaughan, Richmond Hill, Markham and North York. A booked visit has a two-hour arrival window with a text. We give a flat-rate price before work starts. No heat at night counts as an emergency: we’re open 24/7 and technicians go out day or night.

Local page: furnace repair in Mississauga.

Assurance HVAC Heating & Cooling is an independent HVAC contractor, not affiliated with or authorized by Tempstar. Brand names are trademarks of their owners.

FAQ

Tempstar furnace repair questions

Is Tempstar owned by Carrier?

Tempstar is a Carrier Global brand and an International Comfort Products brand, a Carrier subsidiary. That means Tempstar shares a parent with Carrier, Bryant and KeepRite. It doesn’t mean the furnaces share parts, and we don’t claim they do. We match each part to the label on your own unit.

Why does my Tempstar furnace keep shutting off?

The most common causes are a clogged filter, a coated flame sensor, a blocked condensate drain or vent pipe, and a thermostat in a poor location. Replace the filter and clear any snow from the outdoor pipes. If it keeps cycling, stop resetting it and book a diagnosis.

Why is my Tempstar furnace running but not blowing hot air?

It could be a failed igniter or flame sensor, a limit switch that stopped the burners, or a thermostat set to fan on. Check that the thermostat is on Auto. If the air remains cold, turn the furnace off and call us for a repair, since the cause is probably a safety control.

What does a Tempstar furnace flashing light mean?

An F96VTN reports problems as a two-digit blink sequence you can watch through the viewing glass in its door. Code 33 tells you the limit circuit has opened, and a dirty filter is the first suspect; code 32 says the low-heat pressure switch didn’t close. Look up the rest in the table above, since other models can differ.

Can I fix a noisy Tempstar furnace myself?

You can check that the filter is in place, the door is closed and no panels are loose. Anything inside the cabinet, such as burners, the blower or the gas valve, needs a licensed technician. A loud bang at start-up should be checked right away.

Do you repair Tempstar Ion furnaces with Wi-Fi controls?

Yes. Our technicians work on Tempstar furnaces in any series, and we test the furnace and the wall control together. We’re independent and not affiliated with Tempstar. Mention at booking if your control is Wi-Fi so we can check the wiring and settings.

Where is the model number on a Tempstar furnace?

No maker page we could verify says where Tempstar puts its plate. On gas furnaces the label is usually inside the front door or on the cabinet. Ask your technician to find and photograph it, and file the picture with your receipts.

Is Tempstar furnace repair covered under warranty?

Possibly. It turns on the model, the install date and registration, so read your paperwork and the maker’s Canadian warranty page. We don’t perform warranty work on the maker’s behalf. Our own repairs have a written workmanship warranty, and our maintenance plan helps keep service records.

Book a visit

Need Tempstar furnace repair? We’ll call you back to book.

Send the form or call. You’ll get a confirmed arrival window and a price before any work starts.

(647) 692-0819

Open 24/7, with technicians out day or night for no-heat and no-cooling emergencies

Request a technician

Tell us what’s going on. We’ll call to confirm a time.

What do you need?
How soon? Optional
Add an email or detailsOptional

Or call (647) 692-0819Used only to book your visit. Privacy